    摘要:

    高压电缆缓冲层烧蚀故障是近年来频发的电缆故障类型,而目前的烧蚀缺陷检测手段难以满足存量电缆的检测需求。为此,文中首次研究基于铝护套内表面粗糙度的高压电缆缓冲层烧蚀缺陷的超声检测方法。首先,开展潮湿条件下的缓冲层烧蚀模拟实验,并对烧蚀后的铝片进行激光共聚焦显微镜测试以及电化学阻抗谱分析,发现随着烧蚀时间的增加,铝片的表面粗糙度逐渐增大,同时铝片表面的腐蚀程度逐渐加深,对应的缓冲层烧蚀缺陷逐渐加重,表明铝片的表面粗糙度与潮湿条件下缓冲层的烧蚀程度存在关联。其次,对烧蚀后的铝片开展超声检测实验,并通过相邻超声回波信号的幅值比推算出铝片腐蚀面的粗糙度,与实验测得的粗糙度具有相同的变化趋势。文中结果表明超声检测可用于检测缓冲层烧蚀缺陷的严重程度,为高压电缆缓冲层烧蚀缺陷超声检测方法的应用奠定了研究基础。

    Abstract:

    The ablation fault of buffer layers in high-voltage cables is a frequent type of cable fault in recent years. However,current detection methods for ablation defects cannot meet the detection requirements of existing cables. In this paper,the ultrasonic detection method for the buffer layer ablation defects in high-voltage cables based on the surface roughness of aluminum sheath is studied for the first time. Firstly,simulated buffer layer ablation experiments under humid conditions are carried out,and the laser confocal microscopy and electrochemical impedance spectroscopy analysis are carried out on the ablated aluminum specimens. It is found that with the increase of ablation time,the surface roughness of aluminum specimens gradually increases,and the surface corrosion degree of aluminum specimens gradually deepens,corresponding to the aggravated ablation defects of buffer layers,which indicates that the surface roughness of aluminum specimens could be correlated with the ablation degree of buffer layers under the moisture conditions. Secondly,ultrasonic testing experiments are carried out on the ablated aluminum specimens,and the roughness of the corroded surfaces of aluminum specimens can be calculated from the amplitude ratio of adjacent ultrasonic echo signals. The calculated results show the same variation trend as the measured roughness in the experiment. The results in this study indicate that the ultrasonic tests could be used to detect the severity of buffer layer ablation defects,providing the research basis for the ultrasonic detection method of ablation defects in the buffer layer of high-voltage cables.

    参考文献
    相似文献
    引证文献
引用本文

高建,张浩然,张可,李建英.高压电缆缓冲层烧蚀缺陷超声检测实验[J].电力工程技术,2024,43(1):174-180

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2023-08-21
  • 最后修改日期:2023-11-03
  • 录用日期:2023-07-03
  • 在线发布日期: 2024-01-19
  • 出版日期: 2024-01-28
文章二维码